Span Tables Roof Purlin Spacing Australia

Publications Trada Timber Deck Roof Truss Design Roof Beam

Publications Trada Timber Deck Roof Truss Design Roof Beam

Purlin Flat Roof Loafing Shed Roof

Purlin Flat Roof Loafing Shed Roof

Image Result For Deck I Beam Deck Framing Steel Deck Framing Deck Flooring

Image Result For Deck I Beam Deck Framing Steel Deck Framing Deck Flooring

Eaves Roof Detail Drawings Detailed Drawings Roof Detail Plates On Wall

Eaves Roof Detail Drawings Detailed Drawings Roof Detail Plates On Wall

King Post Truss Roof Trusses Roof Truss Design Timber Roof

King Post Truss Roof Trusses Roof Truss Design Timber Roof

Irregular Hip Roof Jack Purlin Compound Angles Hip Roof Roof Roof Framing

Irregular Hip Roof Jack Purlin Compound Angles Hip Roof Roof Roof Framing

Irregular Hip Roof Jack Purlin Compound Angles Hip Roof Roof Roof Framing

High pressure zones kl 1 5 and 2 0 included.

Span tables roof purlin spacing australia.

Step 4 assume the wind classification for the area is n1 and the roofing profile is stramit corrugated cladding 0 48mm bmt thickness in a single span configuration. For 2x6s purlins the posts are spaced in 6 feet distance. If you want to know how to support roof purlins they are usually supported by 2 4 or 2 6 struts or posts. From span table c the maximum allowable single span is 2160mm.

The tables include a comprehensive range of span configurations. Cpe 0 9 and cpi 0 2. Posts these span tables are designed for a minimum post size of 50 x 50 x 2 5mm up to a maximum height of 3 0m. As per as1684 and as4055 spanman adopts a nett pressure coefficient applied along the full length of the purlin of cpn 2 0 for non cyclonic zones n1 to n6 and cpn 2 5 for cyclonic zones c1 to c4.

Cleated or bracketed fixing only no flange bolting. Purlins near roof edges or changes of roof slope are subject to higher wind forces than interior purlins. Max roof span allowed 12m. 02 6554 6422 email.

Safe roof purlins spans. They have been generated using the latest version of the purlin and girt software developed by the centre for advanced structural engineering at the university of sydney and cover the full range of stratco z and c sections from 75mm through to 400mm depth. If the space between posts is greater than 8 feet then brace is needed to avoid buckling. Required size for a given span.

Sizes stramit top hat th64 series th96 series stramit battens 3 97mm approx 36mm 64mm 22mm stramit top hat th64075 th64100 th64120 stramit cyclonic roof batten stramit roof batten stramit ceiling. Spantec has prepared these tables for use by people skilled in the design and specification of the. 29 norfolk close tuncurry nsw 2428 phone. Australian standards such as as1170 series loading codes as4600 cold formed steel structures and as3623 domestic metal framing.

Use recommended minimum roof pitches as specified by roof sheet supplier. Flat roof span tables allow for a maximum roof pitch of 5ยบ. Visit the roof framing page for more information on cutting roof rafters and visit the roof pitch calculator for determining rafter lengths based on rise and run. Roof load width rlw and floor load width flw can be determined from as1684 or from the images below.

For 2x4s purlins the posts are spaced in 4 feet distance. The safe spans below are suitable for sheds and class 1 structures with the following assumptions. All spans to have 1 row of bridging.

Image Result For Dimensions Of Timber Truss Roof Trusses Roof Truss Design Timber Roof

Image Result For Dimensions Of Timber Truss Roof Trusses Roof Truss Design Timber Roof

Chapter 8 Roof Ceiling Construction Ridge Beam Ridge Board Roof Beam

Chapter 8 Roof Ceiling Construction Ridge Beam Ridge Board Roof Beam

Pin By Sergiu Muresan On Details Woodworking Roof Trusses

Pin By Sergiu Muresan On Details Woodworking Roof Trusses

King Post Truss Roof Roof Truss Design Roof Trusses Framing Construction

King Post Truss Roof Roof Truss Design Roof Trusses Framing Construction

Source : pinterest.com